Control Ranger


Description

The Control Ranger is used for defining control ranges to suit different parameter types. It has the same control editing functionality as BCM modules and is compatible with BCM encoder presets.

Type

CONTROL

Module

Control-Ranger.png

Popup

Control-Ranger-Popup.png

Module Connections

Label
Type
Description
Control Range
A
Async
Control to be ranged should be connected here
Bipolar/Unipolar
B
Async
Ranger output for connection to chosen parameter control socket
As defined in Popup Edit Panel

Module Controls

Label
Description
VALUE DISPLAY
Displays value as defined in display page of control edit panel. Control values can also be keyed in directly here

Popup Controls

Label
Description
BIPOLAR TO UNIPOLAR
BCM encoders are unipolar at source so this facilitates encoder preset compatibility for bipolar controls like the Joystick
NAME
Text entry for renaming the control
PRESET BUTTON
Opens preset list which is compatible with BCM encoder presets
PANEL SELECT
BCM Encoder and parameter display buttons marked E and D select between encoder and display edit pages
EDIT PANEL
Identical to BCM Control Editing with exception of MIDI Ctrl assignment